Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 13.206
Filtrar
1.
PLoS One ; 19(4): e0300285, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38564604

RESUMO

Previous research on stabilization methods for microbiome investigations has largely focused on human fecal samples. There are a few studies using feces from other species, but no published studies investigating preservation of samples collected from cattle. Given that microbial taxa are differentially impacted during storage it is warranted to study impacts of preservation methods on microbial communities found in samples outside of human fecal samples. Here we tested methods of preserving bovine fecal respiratory specimens for up to 2 weeks at four temperatures (room temperature, 4°C, -20°C, and -80°C) by comparing microbial diversity and community composition to samples extracted immediately after collection. Importantly, fecal specimens preserved and analyzed were technical replicates, providing a look at the effects of preservation method in the absence of biological variation. We found that preservation with the OMNIgene®â€¢GUT kit resulted in community structure most like that of fresh samples extracted immediately, even when stored at room temperature (~20°C). Samples that were flash-frozen without added preservation solution were the next most representative of original communities, while samples preserved with ethanol were the least representative. These results contradict previous reports that ethanol is effective in preserving fecal communities and suggest for studies investigating cattle either flash-freezing of samples without preservative or preservation with OMNIgene®â€¢GUT will yield more representative microbial communities.


Assuntos
DNA , Manejo de Espécimes , Bovinos , Humanos , Animais , Manejo de Espécimes/métodos , Fezes/química , DNA/análise , Etanol/análise , Sistema Respiratório , Genômica , RNA Ribossômico 16S/genética
2.
Front Cell Infect Microbiol ; 14: 1332157, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38500504

RESUMO

Introduction: SARS-CoV-2 is known to infect respiratory tissue cells. However, less is known about infection of ocular tissue and potential infectivity of lacrimal fluid. With this study, we want to compare viral loads in eye and nasopharyngeal swabs and analyze these for infectious virus. Methods: Between May 2020 and April 2021 ocular and nasopharyngeal swabs were collected from 28 SARS-CoV-2 infected patients treated on the corona virus disease 2019 (COVID-19)-ward of the University Hospital of Innsbruck, Austria. Samples with PCR detectable SARS-CoV-2 were analyzed via whole genome sequencing and an attempt was made to isolate infectious virus. Results: At the time point of sample collection, 22 individuals were still PCR positive in nasopharyngeal samples and in 6 of these patients one or both ocular samples were additionally positive. CT-values in eyes were generally higher compared to corresponding nasopharyngeal samples and we observed a tendency for lower CT-values, i.e. increased viral load, in nasopharyngeal swabs of individuals with at least one infected eye, compared to those where ocular samples were PCR negative. Ocular and nasopharyngeal sequences from the same patient were assigned to the same variant, either the D614G or the Alpha variant. Infectious virus was successfully isolated from 9 nasopharyngeal swabs, however only from one of the seven PCR positive ocular samples. Conclusion: We could detect SARS-CoV-2 in eyes of some of the infected patients albeit at lower levels compared to nasopharyngeal swabs. However, our results also indicate that lacrimal fluid might be infectious in patients with high viral load.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Carga Viral , Nasofaringe , Manejo de Espécimes/métodos , RNA Viral/genética , RNA Viral/análise
3.
Genes (Basel) ; 15(3)2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38540432

RESUMO

In a mass fatality incident (MFI), effective preservation of tissue samples is the cornerstone for downstream DNA-based identification of victims. This is commonly achieved through freezing of tissue samples excised from bodies/fragmented remains which may be buried or stored in refrigerated containers. This may, however, not be possible depending on the nature of the MFI; in particular, during armed conflict/war where extended periods of electrical outages would be expected. The present study compared the effectiveness of long-term tissue preservation at ambient temperatures using two commercial products (non-iodized kitchen salt and a 40% alcoholic beverage) against a chemical preservative (Allprotect™ Tissue Reagent (Qiagen, Germantown, MD, USA)) and freezing at -20 °C. Bovine muscle tissue, used as a proxy for human tissue, was treated with the four preservation methods and sampled at six different time-points over a 24-month period. All four methods were able to preserve the bovine tissue, generally yielding STR-PCR (Short Tandem Repeat-Polymerase Chain Reaction) amplicons > 200 bp in size even at the end of 24 months. Gel electrophoresis, however, indicated that salt was more effective in preserving DNA integrity with high-molecular-weight DNA clearly visible as compared to the low-molecular-weight DNA smears observed in the other methods. This study also proposes a simple process for the rapid and low-cost preservation of tissue samples for long-term storage at ambient temperatures in support of post-incident victim identification efforts.


Assuntos
Incidentes com Feridos em Massa , Preservação de Tecido , Animais , Bovinos , Humanos , Temperatura , Preservação de Tecido/métodos , DNA/genética , DNA/análise , Manejo de Espécimes/métodos
4.
Acta Crystallogr D Struct Biol ; 80(Pt 4): 232-246, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38488730

RESUMO

Single-particle cryo-electron microscopy has become a widely adopted method in structural biology due to many recent technological advances in microscopes, detectors and image processing. Before being able to inspect a biological sample in an electron microscope, it needs to be deposited in a thin layer on a grid and rapidly frozen. The VitroJet was designed with this aim, as well as avoiding the delicate manual handling and transfer steps that occur during the conventional grid-preparation process. Since its creation, numerous technical developments have resulted in a device that is now widely utilized in multiple laboratories worldwide. It features plasma treatment, low-volume sample deposition through pin printing, optical ice-thickness measurement and cryofixation of pre-clipped Autogrids through jet vitrification. This paper presents recent technical improvements to the VitroJet and the benefits that it brings to the cryo-EM workflow. A wide variety of applications are shown: membrane proteins, nucleosomes, fatty-acid synthase, Tobacco mosaic virus, lipid nanoparticles, tick-borne encephalitis viruses and bacteriophages. These case studies illustrate the advancement of the VitroJet into an instrument that enables accurate control and reproducibility, demonstrating its suitability for time-efficient cryo-EM structure determination.


Assuntos
Proteínas de Membrana , Manejo de Espécimes , Microscopia Crioeletrônica/métodos , Reprodutibilidade dos Testes , Manejo de Espécimes/métodos , Processamento de Imagem Assistida por Computador
5.
Diagn Microbiol Infect Dis ; 109(1): 116210, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38452554

RESUMO

This study aimed to improve the heat shock method as a cost-effective and time-efficient for total RNA extraction. We compared the effectiveness of two total RNA extraction methods by using Real-Time PCR for nasopharynx swabs. Include: I; use of a commercial total RNA extraction kit as a standard. II; utilized a modified heat shock method (MHS). Time, centrifuge speed and duration, proteinase K, and RNA carrier were optimized. The optimized parameters included treating the sample with 5 µg/µL at 56°C for 5 minutes, heating at 95°C for 5 minutes followed by thermal shock in ice for 3 minutes, adding 4 µg/µL RNA carrier at room temperature for 3 minutes, and centrifuging at 7000 rpm for 10 minutes. This optimization demonstrated a sensitivity and specificity of 100% (CI: 95%) even in samples with low viral load. Our in-house method presents a rapid, and cost-effective alternative for total RNA extraction.


Assuntos
COVID-19 , Humanos , SARS-CoV-2/genética , Teste para COVID-19/métodos , Técnicas de Laboratório Clínico/métodos , Carga Viral , Nasofaringe , RNA Viral/genética , RNA Viral/análise , Sensibilidade e Especificidade , Resposta ao Choque Térmico , Manejo de Espécimes/métodos
6.
Adv Exp Med Biol ; 3234: 173-190, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38507207

RESUMO

High-resolution structure determination by electron cryo-microscopy underwent a step change in recent years. This now allows study of challenging samples which previously were inaccessible for structure determination, including membrane proteins. These developments shift the focus in the field to the next bottlenecks which are high-quality sample preparations. While the amounts of sample required for cryo-EM are relatively small, sample quality is the key challenge. Sample quality is influenced by the stability of complexes which depends on buffer composition, inherent flexibility of the sample, and the method of solubilization from the membrane for membrane proteins. It further depends on the choice of sample support, grid pre-treatment and cryo-grid freezing protocol. Here, we discuss various widely applicable approaches to improve sample quality for structural analysis by cryo-EM.


Assuntos
Elétrons , Proteínas de Membrana , Microscopia Crioeletrônica/métodos , Congelamento , Manejo de Espécimes/métodos , Substâncias Macromoleculares
7.
Sci Rep ; 14(1): 5171, 2024 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-38431711

RESUMO

Ethical animal use follows the 3R's: Replacement, Reduction and Refinement. Here, we present the use of simultaneous jugular vein and cisterna magna catheterization via a port system in rats for repeated fluid sampling for 14 consecutive days without loss of catheter patency. This technique allows repeated intra-animal sampling without anesthesia and, if used with pooling samples from a cohort of animals, replaces the need for terminal collections for sufficient sample volumes.


Assuntos
Anestesia , Cisterna Magna , Humanos , Ratos , Animais , Cateterismo/métodos , Manejo de Espécimes/métodos , Cateteres , Líquido Cefalorraquidiano
8.
J Virol Methods ; 326: 114912, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38447645

RESUMO

Optimal sampling, preservation, and culturing of SARS-CoV-2 from COVID-19 patients are critical for successful recovery of virus isolates and to accurately estimate contagiousness of the patient. In this study, we investigated the influence of the type of sampling media, storage time, freezing conditions, sterile filtration, and combinations of these to determine the optimal pre-analytic conditions for virus recovery and estimation of infectious viral load in COVID-19 patients. Further, we investigated the viral shedding kinetics and mucosal antibody response in 38 COVID-19 hospitalized patients. We found Universal Transport Medium (Copan) to be the most optimal medium for preservation of SARS-CoV-2 infectivity. Our data showed that the probability of a positive viral culture was strongly correlated to Ct values, however some samples did not follow the general trend. We found a significant correlation between plaque forming units and levels of mucosal antibodies and found that high levels of mucosal antibodies correlated with reduced chance of isolating the virus. Our data reveals essential parameters to consider from specimen collection over storage to culturing technique for optimal chance of isolating SARS-CoV-2 and accurately estimating patient contagiousness.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Carga Viral , Teste para COVID-19 , Manejo de Espécimes/métodos , RNA Viral
9.
Sci Adv ; 10(7): eadl4628, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38354247

RESUMO

Native mass spectrometry (MS) has become widely accepted in structural biology, providing information on stoichiometry, interactions, homogeneity, and shape of protein complexes. Yet, the fundamental assumption that proteins inside the mass spectrometer retain a structure faithful to native proteins in solution remains a matter of intense debate. Here, we reveal the gas-phase structure of ß-galactosidase using single-particle cryo-electron microscopy (cryo-EM) down to 2.6-Å resolution, enabled by soft landing of mass-selected protein complexes onto cold transmission electron microscopy (TEM) grids followed by in situ ice coating. We find that large parts of the secondary and tertiary structure are retained from the solution. Dehydration-driven subunit reorientation leads to consistent compaction in the gas phase. By providing a direct link between high-resolution imaging and the capability to handle and select protein complexes that behave problematically in conventional sample preparation, the approach has the potential to expand the scope of both native mass spectrometry and cryo-EM.


Assuntos
Proteínas , Manejo de Espécimes , Microscopia Crioeletrônica/métodos , Proteínas/química , Espectrometria de Massas/métodos , beta-Galactosidase , Manejo de Espécimes/métodos
10.
J Clin Pathol ; 77(3): 190-203, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38373782

RESUMO

Pathological examination of surgical specimens and compilation of a surgical pathology report comprises a series of events which includes macroscopic examination and tissue sampling, either complete or selected. This step is critical but often overlooked in the literature and not given the attention it deserves. In this review, we discuss the macroscopic examination and grossing of gynaecological pathology specimens, with reference to national and international protocols. We provide guidance as to the degree of sampling necessary in different scenarios and stress that a common-sense approach is necessary with flexibility in the degree of sampling depending on a variety of factors.


Assuntos
Manejo de Espécimes , Humanos , Manejo de Espécimes/métodos , Feminino , Ginecologia
11.
BMC Oral Health ; 24(1): 168, 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38308289

RESUMO

BACKGROUND: Human saliva as a bodily fluid-similar to blood-is utilized for diagnostic purposes. Unlike blood sampling, collecting saliva is non-invasive, inexpensive, and readily accessible. There are no previously published systematic reviews regarding different collection, transportation, preparation, and storage methods for human saliva. DESIGN: This study has been prepared and organized according to the preferred reporting items for systematic reviews and meta-analyses (PRISMA) 2020 guidelines. This systematic review has been registered at PROSPERO (Registration ID: CRD42023415384). The study question according to the PICO format was as followed: Comparison of the performance (C) of different saliva sampling, handling, transportation, and storage techniques and methods (I) assessed for analyzing stimulated or unstimulated human saliva (P and O). An electronic search was executed in Scopus, Google Scholar, and PubMed. RESULTS: Twenty-three descriptive human clinical studies published between 1995 and 2022 were included. Eight categories of salivary features and biomarkers were investigated (i.e., salivary flow rate, total saliva quantity, total protein, cortisol, testosterone, DNA quality and quantity, pH and buffering pH). Twenty-two saliva sampling methods/devices were utilized. Passive drooling, Salivette®, and spitting were the most utilized methods. Sampling times with optimum capabilities for cortisol, iodine, and oral cancer metabolites are suggested to be 7:30 AM to 9:00 AM, 10:30 AM to 11:00 AM, and 14:00 PM to 20:00 PM, respectively. There were 6 storage methods. Centrifuging samples and storing them at -70 °C to -80 °C was the most utilized storage method. For DNA quantity and quality, analyzing samples immediately after collection without centrifuging or storage, outperformed centrifuging samples and storing them at -70 °C to -80 °C. Non-coated Salivette® was the most successful method/device for analyzing salivary flow rate. CONCLUSION: It is highly suggested that scientists take aid from the reported categorized outcomes, and design their study questions based on the current voids for each method/device.


Assuntos
Hidrocortisona , Saliva , Humanos , Hidrocortisona/análise , Saliva/química , Biomarcadores/metabolismo , Manejo de Espécimes/métodos , DNA/metabolismo
12.
J Med Virol ; 96(3): e29426, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38420851

RESUMO

With the rising need for accessible cervical cancer screening, self-sampling methods offer a promising alternative to traditional physician-led sampling. This study aims to evaluate the efficacy of the HygeiaTouch Self Sampling Kit for Women in detecting human papillomavirus (HPV) types and predicting cervical lesions. We studied the concordance in identifying high-risk HPV (hrHPV) types between samples collected by physicians and those self-collected by women using a self-sampling kit for validation. Women aged 21-65, fitting into specific categories based on their cervical health history were eligible. Cohen's kappa coefficient to gauge concordance between the two specimen types and relative accuracy metrics in identifying cervical intraepithelial neoplasia (CIN) were also calculated, with physician-sampled specimens serving as a reference. A total of 1210 participants from three institutes were involved. The self-sampling kit closely matched the physician-led method in terms of collecting valid specimens (100% vs. 100%), identifying hrHPV types (kappa: 0.75, 95% confidence interval [95% CI]: 0.72-0.79; agreement: 87.7%, 95% CI: 85.8-89.6) and predicting CIN grade 2 or worse (CIN2+) (relative sensitivity: 0.949, relative accuracy: 0.959). Kappa values varied between 0.71 and 0.83 for different hrHPV types and combinations, with an overall value 0.75 (95% CI: 0.72-0.79) signifying robust compatibility between the two methods. Our study underscores the potential of the HygeiaTouch Self Sampling Kit as a reliable, efficient, and user-friendly alternative to traditional sampling methods. This suggests that self-sampling could be pivotal in expanding cervical cancer screening accessibility and enhancing detection rates.


Assuntos
Infecções por Papillomavirus , Médicos , Displasia do Colo do Útero , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico , Papillomavirus Humano , Detecção Precoce de Câncer/métodos , Papillomaviridae/genética , Manejo de Espécimes/métodos , Esfregaço Vaginal/métodos , Sensibilidade e Especificidade
13.
Asian Pac J Cancer Prev ; 25(2): 653-659, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38415553

RESUMO

OBJECTIVE: HR-HPV types 16 and 18 are responsible for pre-invasive and invasive lesions of the cervix, accounting for 70-80% of the total subtypes. The aim of this study was to investigate the prevalence of high-risk HPV subtypes 16 and 18 in self-collected vaginal samples using real-time micro-PCR and to study the acceptability of self-sampling. METHODS: Eligible women (30-65 years) were screened from a semi-urban area of Uttarakhand (India) using self-sampling. High-risk HPV genotypes (16/31 and 18/45) were tested using real-time micro-PCR technique with results available in one hour. The positive results were validated by standard RT-PCR for high-risk HPV 16, 18, separately and for 12 other high-risk genotypes, combined. Ease of the procedure, level of comfort, and recommendation to other women were studied and the acceptability of self-sampling was analyzed using the Likert scale. RESULT: Of 975 eligible women screened, 45 participants tested positive for HR-HPV (16/31,18/45) using real-time micro-PCR with a prevalence of 4.6%. Positive samples were further tested through routine RT-PCR and 60% were found to be HR-HPV 16 and 18 positive. For self-sampling, 96.72% (n=943) participants were 'very satisfied' and 94.15% (n=918) found self-sampling to be 'very comfortable' and 88.51% (n=863) stated that they will strongly recommend this test to other eligible women in the community. CONCLUSION: We conclude that HR-HPV testing with limited genotyping showed a prevalence of 4.6%, 60% of these were HPV 16/18 positive. Point of care testing was feasible in the community and self-sampling was acceptable.


Assuntos
Infecções por Papillomavirus , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/epidemiologia , Neoplasias do Colo do Útero/prevenção & controle , Infecções por Papillomavirus/diagnóstico , Infecções por Papillomavirus/epidemiologia , Infecções por Papillomavirus/prevenção & controle , Papillomavirus Humano 16 , Papillomavirus Humano 18 , Programas de Rastreamento/métodos , Manejo de Espécimes/métodos , Testes Imediatos , Papillomaviridae/genética , Detecção Precoce de Câncer , Esfregaço Vaginal
14.
Prev Med ; 180: 107888, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38325609

RESUMO

OBJECTIVE: Denmark went through various COVID-19 pandemic restrictions including periodic lockdowns from March 2020 to January 2022. All cancer screening programs were kept operational, yet access to clinicians for cervical screening was at times limited. We assessed the impact of the pandemic on cervical cancer screening activity in the Capital Region of Denmark. METHODS: Cervical screening activity was defined as regular screening by invitation, opportunistic screening, and screening participation by HPV self-sampling. Activity was monitored during and post-pandemic and compared relatively to a 3-year pre-pandemic reference. RESULTS AND CONCLUSIONS: The activity of cervical cancer screening was initially affected by the pandemic lockdowns, but increased activity during summer 2020 partly compensated this effect. Regular screening activity decreased 8.4% in 2020 and returned to pre-pandemic levels in 2021. During 2022 restrictions were removed and the decrease in activity was recorded to be 2.3%. Opportunistic screening activity was reduced by 14.3% in 2020 and 12.6% in 2021. A continued post-pandemic opportunistic screening activity reduction of 18.5% was observed, possibly related to changed patterns of primary health care use introduced during the pandemic. Screening by HPV self-sampling increased from 17.1% in the pre-pandemic period to 21.2% during the pandemic. Significantly more acceptance was recorded amongst older women (p < 0.0001). This increase mirrors the decrease in total clinician collected sample activity during the pandemic, where an increased reduction by age was observed. Post-pandemic HPV self-sampling participation decreased to 12.8%, possible reflecting a temporarily changed composition and motivation in the group of women invited for self-sampling.


Assuntos
COVID-19 , Infecções por Papillomavirus , Neoplasias do Colo do Útero , Feminino , Humanos , Idoso , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/prevenção & controle , Neoplasias do Colo do Útero/epidemiologia , Detecção Precoce de Câncer/métodos , Pandemias/prevenção & controle , Esfregaço Vaginal , Infecções por Papillomavirus/diagnóstico , Papillomaviridae , Autocuidado/métodos , COVID-19/diagnóstico , Controle de Doenças Transmissíveis , Manejo de Espécimes/métodos , Programas de Rastreamento/métodos , Dinamarca/epidemiologia
15.
Eur J Obstet Gynecol Reprod Biol ; 296: 20-51, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38394715

RESUMO

Cervical cancer is the third most common gynecological cancer worldwide. Its origin is linked to intraepithelial lesions caused by high-risk Human Papillomavirus (HPV) types, detected in 99.7% of cases. Early screening is essential to prevent cancer development from these lesions. Molecular methods are more specific and offer the possibility of being performed through a self-collected sample by the patient, thus contributing to increasing screening coverage for this pathology. This study aim was to map the medical-scientific literature on existing protocols for self-sampling for HPV testing in cervical cancer screening. A search strategy was developed using the following keywords and their synonyms: "self-sampling," "professional sampling," and "HPV", on the databases: MEDLINE, Cochrane Library, Virtual Health Library - BVS, Scopus, National Institute for Health Research NHS EED, Web of Science, and EMBASE. The search strategy was formulated to identify relevant studies and describe their main characteristics, such as patient acceptance of self-sampling, cost differences between the tests used, and the accuracy of self-sampling compared to the gold standard test. A total of 876 studies were found, and 33 of those studies were included in this review. Out of these, 10 studies were domized clinical trials involving 46,751 patients, and 23 observational studies included 142,795 patients. Regarding acceptance, most studies reported a preference for self-sampling. Sensitivity analyses from various studies also showed that the low cost of self-sampling kits generally increased cost-effectiveness. The study concluded that using HPV testing on self-collected samples is a viable strategy for monitoring women with HPV.


Assuntos
Infecções por Papillomavirus , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico , Detecção Precoce de Câncer/métodos , Autocuidado , Manejo de Espécimes/métodos , Programas de Rastreamento/métodos , Papillomaviridae
16.
Clin Lab Med ; 44(1): 33-43, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38280796

RESUMO

As infectious disease diagnostics increasingly incorporates molecular techniques, there are unique preanalytical concerns that must be considered. First, noninvasive specimen types that may be inadequate for culture-based diagnostics may be acceptable when using molecular tests. Second, specimen containers must be evaluated for the presence of substances that may interfere with amplification or sequencing reactions. Finally, the capacity of transport, storage, and processing conditions to maintain nucleic acid integrity and avoid contamination must be assessed. This review explores these issues and the effects they may have on result quality.


Assuntos
Técnicas Microbiológicas , Manejo de Espécimes , Manejo de Espécimes/métodos
17.
Methods Mol Biol ; 2742: 245-257, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38165627

RESUMO

Availability of relevant biological samples supports both basic science research and patient-centered clinical studies. Establishing a biorepository faces challenges at multiple levels. These tasks include defining mission definition and scope; selection of subjects and sample types; recruitment strategies; timing of collection in the patient's journey; sample logistics and processing; determining what clinical data to collect; ensuring sample integrity on transport, processing, and storage; defining governance structures and oversight responsibilities; clarifying sample provenance and ownership; establishing procedures for sample and data access; selecting testing to be performed routinely versus upon request, and management of results; data security; funding sources; and regulatory compliance. Establishing and maintaining a biorepository therefore requires careful planning, diligent and sustained execution, technical and financial resources, stakeholder support, and flexible and resilient management to respond to changing environments and needs.


Assuntos
Bancos de Espécimes Biológicos , Manejo de Espécimes , Gravidez , Feminino , Humanos , Manejo de Espécimes/métodos
18.
PLoS One ; 19(1): e0292731, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38285680

RESUMO

Canine fecal microbiota profiling provides insight into host health and disease. Standardization of methods for fecal sample storage for microbiomics is currently inconclusive, however. This study investigated the effects of homogenization, the preservative RNAlater, room temperature exposure duration, and short-term storage in the fridge prior to freezing on the canine fecal microbiota profile. Within 15 minutes after voiding, samples were left non-homogenized or homogenized and aliquoted, then kept at room temperature (20-22°C) for 0.5, 4, 8, or 24 hours. Homogenized aliquots then had RNAlater added or not. Following room temperature exposure, all aliquots were stored in the fridge (4°C) for 24 hours prior to storing in the freezer (-20°C), or stored directly in the freezer. DNA extraction, PCR amplification, then sequencing were completed on all samples. Alpha diversity (diversity, evenness, and richness), and beta diversity (community membership and structure), and relative abundances of bacterial genera were compared between treatments. Homogenization and RNAlater minimized changes in the microbial communities over time, although minor changes in relative abundances occurred. Non-homogenized samples had more inter-sample variability and greater changes in beta diversity than homogenized samples. Storage of canine fecal samples in the fridge for 24 h prior to storage in the freezer had little effect on the fecal microbiota profile. Our findings suggest that if immediate analysis of fecal samples is not possible, samples should at least be homogenized to preserve the existing microbiota profile.


Assuntos
Microbiota , Animais , Cães , Fezes/microbiologia , Congelamento , Manejo de Espécimes/métodos , Bactérias/genética , Temperatura , RNA Ribossômico 16S/genética
19.
Microbiol Spectr ; 12(3): e0368423, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38289934

RESUMO

Pooled testing combined with molecular diagnostics for the detection of SARS-CoV-2 is a promising method that can increase testing capacities and save costs. However, pooled testing is also associated with the risks of decreased test sensitivity and specificity. To perform reliable pooled testing, we developed and validated three automated media pooling and molecular diagnostic systems. These pooling systems (geneLEAD-PS, Panther-PS, and Biomek-PS) comprised existing automated molecular detection platforms, corresponding automated media pooling devices, and laboratory information management systems. Analytical sensitivity analysis and mock sample evaluation were performed, and the obtained data were used to determine the sizes of the pool for the validation study. In the validation study, a total of 2,448, 3,228, and 6,420 upper respiratory samples were used for geneLEAD-PS, Panther-PS, and Biomek-PS, respectively, and the diagnostic performances were compared with the reference RT‒PCR assay. A pool size of 6 for geneLEAD-PS and a pool size of 4 for Panther-PS and Biomek-PS were selected for the validation studies. All three systems showed high positive percent agreement values of ≥90.5% and negative percent agreement values of ≥99.8% for any specimen type. Pooled testing resulted in a 65%-71% reduction in cost per sample. The testing capacities of geneLEAD-PS, Panther-PS, and Biomek-PS were 144 samples in 3 hours, 384 samples in 5.5 hours, and 376 samples in 4 hours, respectively. The developed pooling systems showed robust diagnostic performances and will increase the testing capacities of molecular diagnostic tests while saving costs and may contribute to infection control of COVID-19.IMPORTANCEDuring the COVID-19 pandemic, there have been surges in demand for accurate molecular diagnostic testing and laboratory supply shortages. Pooled testing combined with highly sensitive molecular testing, which entails mixing multiple samples as a single sample, is a promising approach to increase testing capacities while reducing the use of consumables. However, pooled testing is associated with risks that compromise diagnostic performance, such as false negatives due to dilution of positive samples or false positives due to cross-contamination. To perform reliable pooled testing, three different pooling systems (an automated pooling device, an automated molecular detection platform, and a laboratory information management system) were developed to accurately interpret pooled testing results. These three systems were validated using multiple clinical samples and showed high concordance with individual testing. The developed pooling systems will contribute to increasing reliable molecular testing capacities while using fewer consumables and saving costs.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/epidemiologia , Patologia Molecular , Teste para COVID-19 , Pandemias , Manejo de Espécimes/métodos
20.
Bioanalysis ; 16(4): 203-217, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38226838

RESUMO

Background: Clinical dosage of toxic and essential elements in blood is well established and the collection method is still by venipuncture. This method has drawbacks and is not suited for everyone. Volumetric absorptive microsampling (VAMS) has been shown to have advantages over venipuncture. Materials & methods: Using inductively coupled plasma tandem mass spectrometry, a method for quantifying elements in whole blood sampled on VAMS was developed/validated. Method's performance was assessed by comparison with whole blood results. Results: Validation and performance assessment tests tend to show that most of the targeted elements provides accurate and reproducible results comparing to a method of reference. Conclusion: Overall, VAMS presents good preliminary results to eventually become an alternative to venipuncture for blood sampling for some trace elements analysis purposes.


Assuntos
Espectrometria de Massas em Tandem , Oligoelementos , Espectrometria de Massas em Tandem/métodos , Coleta de Amostras Sanguíneas/métodos , Manejo de Espécimes/métodos , Teste em Amostras de Sangue Seco/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...